Insulation & Earth Resistance Tester

Clamp grounding resistance tester

type:UT276A+

UT276A+clamp grounding resistance tester is applicable to special occasions that cannot be measured by traditional methods, such as building lightning protection grounding system, gas station grounding system, transformer neutral point, power plant substation and other grounding condition detection.

Online Service

TAGS:

  • Product Introduction

UT276A+adopts clamp grounding resistance test technology, without using any auxiliary grounding pile, without interrupting the grounding wire of the equipment to be tested, which greatly simplifies the grounding circuit test process and allows non-intrusive leakage current measurement. The thin film alloy clamp head is used to strengthen the anti-interference ability of the clamp head. It has the resistance limit alarm function and can set the alarm value within the range. The fuselage is small and delicate, durable, and has backlight function, which can cope with narrow, dark and harsh measuring environment. The opening size is 32mm, which is compatible with most of the size of the grounding resistance to be measured.

UT276A+clamp grounding resistance tester is applicable to special occasions that cannot be measured by traditional methods, such as building lightning protection grounding system, gas station grounding system, transformer neutral point, power plant substation and other grounding condition detection.


  • Product Parameters
Measurement modeMeasuring rangeResolving powerAccuracy
Resistance0.010~0.099Ω0.001Ω±(1%+0.01Ω)
0.1~0.99Ω0.01Ω±(1%+0.01Ω)
1~49.9Ω0.1Ω±(1%+0.1Ω)
50.0~99.5Ω0.5Ω±(1.5%+0.5Ω)
100~199Ω±(2%+1Ω)
200~395Ω±(5%+5Ω)
400~590Ω10Ω±(10%+10Ω)
600~880Ω20Ω±(20%+20Ω)
900~1200Ω30Ω±(25%+30Ω)
Current0.00~9.95mA0.01mA±(2.5%+1mA)
10.0~99.0mA0.1mA±(2.5%+5mA)
100~300mA1mA±(2.5%+10mA)
0.30~2.99mA0.01A±(2.5%+0.1A)
3.0~9.9mA0.1A±(2.5%+0.3A)
10.0~20.0mA0.1A±(2.5%+0.5A)
Resistance resolution0.001Ω
Opening size32mm
Measurement time0.5s
Weight1180g


  • Product Features

1. Wide grounding circuit resistance measurement range (0~1200 Ω), which can meet the measurement requirements of the user

2. 32mm into the jaw, can test various grounding levels and equipotential bus

3. The AC current measurement range is 0-20A, and leakage current detection can be carried out, which can be measured without disconnection. It is very suitable for system fault diagnosis

4. User defined HI/LO alert limits

5. Data retention function for obtaining stable readings in inaccessible places

6. Time-saving storage function is convenient for users to check the test data and draw table reports after measurement


Please leave the product information you want to know!