:2023-07-10 10:02:30:
The common faults and handling methods of DC high-voltage generators are as follows:
1. Abnormal output voltage:
It may be caused by issues such as power failure, output circuit short circuit, or open circuit. The treatment method includes checking the power supply and confirming whether the power supply is normal; Check the output circuit, repair or replace the short or open part.
2. Unstable output voltage:
It may be caused by power fluctuations, load changes, or aging of internal components. The handling method includes checking the power supply and resolving fluctuations; Ensure stable load and check if internal components need to be replaced or repaired.
3. Temperature too high:
It may be caused by overload, poor ventilation, or radiator failure. The treatment methods include reducing the load to prevent overload, providing sufficient ventilation and heat dissipation, and checking whether the radiator works properly and repairing or replacing it.
4. Arc or discharge phenomenon:
It may be caused by electrode wear, aging or contamination of insulation materials, improper electrode spacing, and other reasons. The treatment methods include replacing worn electrodes, cleaning or replacing insulation materials, and adjusting the appropriate electrode spacing.
5. Control circuit failure:
It may be caused by issues such as damage to control circuit components, connection faults, or control signal failure. The handling method includes checking the control circuit, repairing or replacing damaged components, and ensuring the normal transmission of control signals.
It should be noted that before dealing with any generator faults, the power supply should be cut off and necessary safety measures taken to ensure the safety of operators. In addition, for those unfamiliar with repairing and handling high-voltage equipment faults, it is best to hire professional technical personnel for repair and handling.
ZC-540A DC high-voltage generator is a new generation of portable DC high-voltage tester designed and manufactured according to the new Chinese power industry standard DL/T848.1-2004 General-purpose technology Conditions for DC High Voltage Generators. Mainly suitable for DC withstand voltage testing of high-voltage electrical equipment such as zinc oxide lightning arresters in power departments, industrial and mining, metallurgical, steel and other enterprises.
Kvtester Electronics Technology Co.,Ltd. is a high-tech enterprise specializing in power testing, testing, research and development, production, and sales of testing equipment. It has been engaged in the electrical testing industry for many years, and its products are of high quality. We welcome customers to come and purchase.